Case study · Novartis Africa, Reading
From a key lock to a push pad
A standard lock on an escape door is one of the most common faults we find on business-park units. The door may have been fitted as a back entrance years ago, the building gets re-occupied, and nobody revisits the hardware even though the door is now on the fire escape route with a sign over it. Under the Regulatory Reform (Fire Safety) Order an emergency exit has to be openable easily and immediately by anyone who needs to use it, without a key. The upgrade at Novartis Africa replaced the lock with a push-pad exit device on the lock stile: one push on the pad releases the latch, and the door relocks itself when it closes.
Push pads, like lever handles, are emergency exit devices for doors used by people who know the building, such as the staff of an office. Where an exit serves members of the public who may not know it, the right device is usually a full-width push bar or touch bar, the panic hardware covered by BS EN 1125. Which one a door needs depends on who uses it, and our guide to BS EN 1125 and EN 179 sets out the difference. The device and the closer have to be set up together: a transom closer that closes the door too softly will leave the latch sitting on the keep, and an exit door that has not latched is neither secure nor fire-safe.
The closer, the device and the door working as one
The worn transom closer was a Dorma RTS 85, and its replacement is a new Dorma closer in the same head cut-out, so the frame was not altered. With the new closer driving the leaf and the push pad on the lock stile, the first clip shows the door being opened from inside with the pad, swung out over the path and released to close and latch on its own. For other exit-door hardware work see our panic hardware repairs.
Work completed at Novartis Africa, Reading
- Scope — transom closer replacement and lock upgrade on the single blue aluminium exit door.
- Removal — leaf lifted off; worn Dorma RTS 85 transom closer and the standard lock removed.
- Closer — new Dorma transom closer fitted into the existing head cut-out.
- Panic hardware — standard lock replaced with a push-pad exit device with a Push to open label.
- Setting — leaf re-hung; closer set so the door closes and latches the device every time.
- Testing — door opened from inside on the push pad and released repeatedly to confirm latching.
Fire exit and panic hardware work in Reading
Commercial Door Maintenance and Security Ltd covers Reading and the Thames Valley business parks, from Theale and Winnersh to Bracknell and Slough, for exit-door hardware, closers and aluminium doors. Send a photograph of the inside of the door with its lock and we can say whether it needs a push pad, a push bar or a touch bar before anyone visits. See also our industrial and business-unit doors page.