Blue aluminium door leaf lifted off and leaning against the clad wall outside the Novartis Africa unit in Reading, with a stepladder in the open doorway

Transom Closer Replaced and Lock Upgraded to Panic Hardware at Novartis Africa, Reading

A single blue aluminium door in a clad business unit, with a fire exit sign over it and a call point beside it, that still needed a key to lock and unlock. We replaced its worn transom closer and swapped the standard lock for a push-pad exit device, so the way out is now one push.

Read the case study
Share this jobFacebookXLinkedInWhatsAppEmail
Back

An exit door that should not need a key

Novartis Africa’s Reading premises are a unit in a business park of grey profiled-cladding buildings with blue window frames, and this blue aluminium door is the one that leads from the office out to the car park. It has a green running-man sign over it on the inside and a fire alarm call point on the wall beside it, so whatever else it does, it is an escape route. It had two problems: the concealed transom closer in its head was worn out, and it was fitted with a standard lock, which on an exit door means somebody has to find a key or a handle before they can get out.

The leaf was lifted off and leaned against the cladding beside the doorway. The transom was opened, the old Dorma RTS 85 removed and a new Dorma closer fitted in its place, and the lock was upgraded to a push-pad exit device with a green “Push to open” label: push the pad and the latch withdraws, let go and the door closes and latches again under the new closer. The leaf was re-hung and the door pushed open and released several times to set the closer so that it latches the device every time. The old and new closers on the block paving outside are in the second clip.

Blue aluminium exit door at Novartis Africa, Reading, with the new push-pad exit device and Push to open label beside a fire alarm call point
Old Dorma RTS 85 transom closer and the new Dorma closer laid side by side on the block paving outside the Novartis unit
Inside face of the blue aluminium door at Novartis Africa with the blind drawn and the push-pad exit device fitted on the lock stile

“If the way out needs a key, it is not a way out. A push pad turns a locked door into an exit in one movement.”

Case study · Novartis Africa, Reading

From a key lock to a push pad

A standard lock on an escape door is one of the most common faults we find on business-park units. The door may have been fitted as a back entrance years ago, the building gets re-occupied, and nobody revisits the hardware even though the door is now on the fire escape route with a sign over it. Under the Regulatory Reform (Fire Safety) Order an emergency exit has to be openable easily and immediately by anyone who needs to use it, without a key. The upgrade at Novartis Africa replaced the lock with a push-pad exit device on the lock stile: one push on the pad releases the latch, and the door relocks itself when it closes.

Push pads, like lever handles, are emergency exit devices for doors used by people who know the building, such as the staff of an office. Where an exit serves members of the public who may not know it, the right device is usually a full-width push bar or touch bar, the panic hardware covered by BS EN 1125. Which one a door needs depends on who uses it, and our guide to BS EN 1125 and EN 179 sets out the difference. The device and the closer have to be set up together: a transom closer that closes the door too softly will leave the latch sitting on the keep, and an exit door that has not latched is neither secure nor fire-safe.

The closer, the device and the door working as one

The worn transom closer was a Dorma RTS 85, and its replacement is a new Dorma closer in the same head cut-out, so the frame was not altered. With the new closer driving the leaf and the push pad on the lock stile, the first clip shows the door being opened from inside with the pad, swung out over the path and released to close and latch on its own. For other exit-door hardware work see our panic hardware repairs.

Work completed at Novartis Africa, Reading

  • Scope — transom closer replacement and lock upgrade on the single blue aluminium exit door.
  • Removal — leaf lifted off; worn Dorma RTS 85 transom closer and the standard lock removed.
  • Closer — new Dorma transom closer fitted into the existing head cut-out.
  • Panic hardware — standard lock replaced with a push-pad exit device with a Push to open label.
  • Setting — leaf re-hung; closer set so the door closes and latches the device every time.
  • Testing — door opened from inside on the push pad and released repeatedly to confirm latching.

Fire exit and panic hardware work in Reading

Commercial Door Maintenance and Security Ltd covers Reading and the Thames Valley business parks, from Theale and Winnersh to Bracknell and Slough, for exit-door hardware, closers and aluminium doors. Send a photograph of the inside of the door with its lock and we can say whether it needs a push pad, a push bar or a touch bar before anyone visits. See also our industrial and business-unit doors page.

One push to open, closing on its own

First clip: the blue exit door from inside under the green running-man sign with the call point beside it, then the push pad pressed, the door swung out onto the path and released to close and latch on the new closer.

Second clip: outside the unit, the leaf leaning against the cladding and the stepladder in the doorway, then down to the old Dorma RTS 85 and the new closer side by side on the paving.

Exit door still on a key lock?

Call 0800 774 7998
▶︎ Watch this video on its own page →
▶︎ Watch this video on its own page →
Project summary

At a glance — Novartis Africa, Reading

  • Client: Novartis Africa
  • Sector: Business-park unit — offices in a clad industrial building
  • Location: Reading, Berkshire
  • Door: Single blue aluminium framed glass door to the car park, on the fire escape route
  • Fault: Worn Dorma RTS 85 transom closer; standard key lock on an exit door
  • Works completed: New Dorma transom closer; lock upgraded to a push-pad exit device; closer set to latch the device
  • Outcome: Door opens from inside with one push and closes and relocks on its own
  • Coverage: Reading and the Thames Valley — and nationwide for multi-site businesses
Talk to an engineer

Same-day quote from a photo — UK-wide commercial door engineers.

Send a photo and a short description of the fault and we’ll come back with a fixed-price quote the same day. Most diagnoses don’t need a site visit.

0800 774 7998 info@cdms-ltd.co.uk Send a photo
Share this case studyFacebookXLinkedInWhatsAppEmail

Project facts

ClientNovartis Africa
LocationReading, Berkshire
Service categoryPanic Hardware Repair
SectorIndustrial sector page →
CoverageUK-wide commercial door specialists — same-day quotes, time-served engineers

Compliance considerations

Panic hardware on public emergency exits must comply with BS EN 1125. Emergency exit hardware on staff-only exits must comply with BS EN 179. Both must carry a CE / UKCA mark with the relevant standard. Removal or modification of certified hardware invalidates compliance.

Maintenance recommendations

Panic hardware should be operationally tested at least monthly by the responsible person and professionally inspected annually. Latch, spring and bar action must be confirmed; bent bars or missing certification marks require replacement of the unit.

Need similar work for your premises?

We complete panic hardware repair across the UK. Send a description, photo or short video and we’ll come back the same day with a written quote — no site visit needed in most cases.

Understand the fault behind this job

Watch similar repairs

All repair videos →

Related case studies

Browse all case studies →

Call now 0800 774 7998 Same-day Quote

Get in touch

Head Office:
Commercial Door Maintenance and Security Ltd
61 Bridge Street,
Kington,
HR5 3DJ

t: 0800 774 7998
e: info@cdms-ltd.co.uk

Office Hours

Mon - Sat: 8am - 10pm
Sun: Closed

© 2026, Commercial Door Maintenance and Security Ltd. All rights reserved. · Terms of Business